Compressed Air Security Measures
- Thursday, February 21st, 2008, 14:17
- Compressed Air
- 48 views
- 1 Comment
1.1 Personal PROTECTION EQUIPMENT
Company officials; machine used and the personnel to take all the safety measures to comply with all protection standards must be sensitive and careful.
1.2 PRESSURE RELEASE of the
A. Compressor and air tank air outlet pipe mounted between the valve should be one. And repair of all types are similar to the air in the tank discharge valve from closing down just this, you will save time and provide security.
B. Appropriate device for your work more efficient compressors, air hose, pipes and filters to select. Select the device and all of the operating pressure of the compressor capacity is absolutely appropriate to make sure.
C. All compressed air connections, a good way to prevent accidental opening check was done.
D. Any fitting, hoses, valves or filters such as the connection element, such as dismantling all internal pressure to empty. First, then close the compressor discharge pressure in the tank (manometer at a value of 0) appears. Lead to any side and to avoid injury after closing compressor tank to reduce the wait for the oil bubble. Separator tank pressure when the oil plug removal in case of any element or heat and pressure can cause injury, do not forget to flush the oil.
E. The output of compressed air directly from any point in human and Keep alive. Do not hold the people and live on the compressed air. Do not breathe the air produced by compressor.
F. To avoid serious accidents and injuries caused by air hose not kidding.
G. Police try to change the factory settings pressostatı and safety ventilinin not.
1.3 FIRE AND EXPLOSION
A. Compressor, or any flammable oils in and around the pond when you see the article immediately clear.
B. Compressor off, and allow to cool. Later, sparks, flame or other fire will form, and eliminate the causes of doing this certainly allow it to be around smokers.
C. Fat sound insulation on the outer surface of the compressor, or certainly do not let the accumulate in the cabin. If necessary, we will clean the deposits obtained from a suitable cleaner. If necessary, remove the foam sound insulation, and replace. Flammable materials in the cleaning process is definitely damaged.
D. If the repair, cleaning or going to take any action within the cabin of the compressor energy absolutely sure.
E. Keep electrical and pressure connections in good condition. Cable insulation is damaged or disconnected immediately change. All electrical and pressure connections, clean and on a regular basis Keep.
F. Grounded or conductive materials, not to cause any fire, the electrical parts on the test strip.
G. If it's going to be affected by heat and sound insulation materials such as sponge and remove the dismantling.
H. Working properly and consistently filled with a fire extinguishing device of the compressor to keep in close.
I. Been in contact with the oil from the compressor Keep all cloth or rubbish.
J. In the event that a proper flow of cooling air compressor run definitely.
K. Any hazardous environmental conditions appropriate to that situation in the compressor and compressor run certainly not been specially produced.
EDEN 1.4 MOVEMENT PARTS
A. Hands, arms, and clothes Keep away from moving parts of machinery parts.
B. Compressor running, fan, belts and other moving parts as possible away from here for not to be caught.
C. Moving around the compressor and hot parts, and especially if you as much as possible through close-fitting clothing to wear your hair is longer and collect.
D. If you are not making any adjustment or repair to keep lids closed.
E. Compressor running all the staff; outburst, explosion and may cause damage of thrown away to protect the compressor in the hold.
F. Before you begin the process of a repair or adjustment of any person's accidental electrical connection of the compressor for the compressor is running it does take the power source.
Compressors are remotely controlled, in this case, warning signs and labels to indicate on the compressor is absolutely essential.
G. Hands, feet and especially to walk the corridors Keep away from oil and water that cause any slip or fall event.
H. Where the compressor is running to ensure adequate lighting.
1.5 HOT SURFACES, SİVRİ sides and corners
A. Hot surfaces, hot oil, to avoid contact with sharp edges and corners.
B. Point out that all of the air Keep your body.
C. If you are working on the compressor, such as gloves and other protective clothing dress header.
D. One first aid kit handy. In case of any injury, call your doctor. Infections can lead to disregard minor abrasions and burns, do not.
And irritants of 1.6 ZEHİRLİ
A. Do not breathe the air pressure from the compressor.
DANGER!
Directly from the compressed air to breathe can cause serious injury and even death.
B. Directly in compressed air lines, and this certainly do not use respiratory equipment provider. In addition, these devices do not have air conditioning or off the air certainly not empty rooms.
C. Only with adequate ventilation compressor run in sections.
D. Compressor, air inlet of the corrosive, toxic or a place where it away from steam output place.
E. Typically used in an industrial compressor oil is oil. Avoid body contact with this oil. Such an event occurs, the oil in contact with soap and water, rinse the area. For information about filling your compressor oil lubrication in this guide, see section.
SHOCK 1.7 reviews
A. This user guide located on compressor and all standards in accordance with the directives should be installed. The electrical connection is required to process a qualified electrician.
B. All regions of your body, hand tools, and conductive materials, over the last pieces Keep electricity. The electrical parts or a repair on the machine you're setting your feet wet and not pay attention to a nonconducting substance found on the name. All repair and setting up operations with one hand and right-handed as possible in case of electric shock, do that any way electricity flows through the heart of the reduced get a chance.
C. Repair process, dry, clean, well-lit and in an environment with good ventilation, do.
D Compressor Keep your electric Fridge door always closed. If you need to open the main switch stopping the compressor from the compressor to the final energy.
E. Before touching any ungrounded conductors or electrical components before making a setting in the final energy of the compressor.
F. Assembly before running after the first check all the devices carefully.
1.8 LIFTING AND CARRYING
A. If the compressor is possible to remove the forklift, but it is not possible, as shown in the following manner to remove the suspension.
B. Before the process of removing the necessary resources and that it points to a problem that may be loose nuts and screws to review.
C. And support for the removal of all the devices you will use is in good condition and the capacity to carry the weight of compressor make sure. If you are not sure of the compressor weight, first compressor to start the removal process and then weighed.
D. When you remove compressor to avoid damage to encourage you to act very carefully.
E. When you remove the compressor under the machine make sure nobody does not stop.
F. Do not remove the extra compressor.
G. The person who made the removal process when the compressor of the compressor to see the hanging, the better.
H. Carry the weight of location to place compressor compressor can be sure of stability.
I. Before you remove the compressor is set a very good forklift feet, make sure.
J. Be careful not to remove the extra forklift machine and move very slowly and carefully.
K. Before you remove the compressor and compressor pallet forklift pallet securely mounted to make sure. Pallet mounted properly or the connection is not corrupt absolutely do not remove the compressor, otherwise serious personal injury and accident path can be opened.
1.9 MAJOR ISSUES
A. If the compressor can enter into people in the greater machine and any person making a transaction of this situation, we notify other personnel and machine keep their doors open so that staff mistakenly machine to run inside and the people working to prevent the injury.
B. Before closing the lid of the compressor in the machine is not anyone's Note.
C. After any repair or adjustment of parts in the machine, cleaning agents or measurement equipment did not stay to make sure.
D. After any repair or settings make sure you have inserted all of the enclosure.
E. No moving parts make sure not to rub the ground.
F. Do not expose the cables carrying electricity.
About the Author
"Compressed Air Safety Measures" for 1 Comments
Let your comment
If you want to appear in your profile picture gravatar a can register for free.





Apartment building is considered to be particularly compressors and provide information important to the user for maddeler.Paylaşım thanks.